   1UControl Tools:

MulticastDiscoveryApp.exe This application will test your network to see if 1UControl can Multicast across your Router or switch.
How to:
1) To Use: Place this exe on 2 PC's that have a router or switch between them.
1a) Close the 1UClient.exe if it running on the PC under test. ( hit Cntrl+Alt+Delete and look in the processes for 1UClient.exe and close it if it's running)
2) Have an assistant click "Start Manual"
3) in the Screens you will see 1 That you are broadcasting locally and the other window will display any clients that are broadcasting on the network.
4) If any clients are found they will be listed in the Discovered Window. these Units are working properly.
MulticastDiscoveryApp.zip
WireShark is a  great network Packet analysis program.
 
wireshark-setup-0.99.6a.exe
Device IR and Serial Command Codes Spreadsheet IRCodesDB.xls

     Trouble-Shooting Information:

Problem: 429 ActiveX error
Cause: The DAO Database Engine did not register properly on the Install.
   Solution: Manually register the DLL into the registry.

1) Open Explorer and go to:
C:/program files>Common files Microsoft Shared>DAO >DAO350.dll

2) Right click on the DAO350.dll and open with Regsver32. *Special Note for Vista:
check run all users XP2.
Problem: 1UControl not connecting to 1UAdmin on the network
Set the "AdminIP" address in the (Administrator Settings parameter) of the Local 1UControl Software and restart the software.
This IP-Value must be the IP Address that the Administrator Software resides on.

Note: for the Client System to be enabled for the Administrator System the "Enable Admin" Parameter must also be set to TRUE.
Problem: 1UAdmin can't see a Client on the network

Check the Following:

1) Check Your Router/Switch can pass Multicast packets on IP 239.255.250.251 Port 9132
2) Check The TTL setting is at least 64 in the Progconfig.ini file
3) Check the IP's of the 1U-Client systems for ip duplication or conflicts
4) Check that the 1UClient.exe Server is running in the processes on the Clients PC
4) Check that each room setup (Profile) has a different "Room Name" ...

If you set up 2 rooms with the same Building name and the same Room Name the ADmin will not see them ... All Systems may have the same Building Name but not the same room name. Also if you change a room-name the software must be re-started to take effect.

1UControl uses the Following IP and port for Admin to 1UClient communications:
Multicast IP = 239.255.250.251
Multicast Port = 9132

Problem: 1UControl locks-up when opening the System-Admin Properties Tab:

This problem has found to be caused by using 800x600 screen resolution, 1UControl must be run at 1024x768 or higher screen resolution. Change your screen resolution and restart the software.

 

Downloads\Docs\Carmel Clay.zip
 